UV radiation dosimeter with double spectral conversion


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The possibility of double spectral conversion of UV radiation from the spectral range of 240–280 nm to the visible spectral region using luminescent glasses and fibers with antimony ions and molecular silver clusters is shown. Planar and fiber prototypes of UV radiation dosimeters are tested. It is shown that the sensitivities of dosimeter of the first and second types are 1400 and 360 mV/W/m2, respectively.

Sobre autores

D. Chernakov

ITMO University

Email: sidorov@oi.ifmo.ru
Rússia, St. Petersburg, 197101

A. Sidorov

ITMO University

Autor responsável pela correspondência
Email: sidorov@oi.ifmo.ru
Rússia, St. Petersburg, 197101

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Pleiades Publishing, Ltd., 2017