Dynamic circlage in case of retinal detachment
- Authors: .Khasanova N.K.1, Valimukhametova N.A.1, Fedorova N.V.1
-
Affiliations:
- Department of Eye Diseases of the Kazan Order of the Red Banner of Labor of the Medical Institute named after S. V. Kurashova
- Issue: Vol 63, No 1 (1982)
- Pages: 27-28
- Section: Articles
- URL: https://bakhtiniada.ru/kazanmedj/article/view/59784
- DOI: https://doi.org/10.17816/kazmj59784
- ID: 59784
Cite item
Full Text
Abstract
Abstract. Twenty-seven operations of circular scleral depression were performed during detachment of the mesh shell using a tape made of domestic silicone rubber. Complete retinal adhesion occurred in 23 eyes, incomplete - in 2; in 2 eyes the retina is not attached. Circular indentation of the sclera during retinal detachment with silicone rubber reduces the risk of cutting the sclera. The indentation shaft constantly tends to come close to the mesh. t Key words: retinal detachment, treatment.
Keywords
Full Text
##article.viewOnOriginalSite##About the authors
N. Kh. .Khasanova
Department of Eye Diseases of the Kazan Order of the Red Banner of Labor of the Medical Institute named after S. V. Kurashova
Author for correspondence.
Email: info@eco-vector.com
Russian Federation
N. A. Valimukhametova
Department of Eye Diseases of the Kazan Order of the Red Banner of Labor of the Medical Institute named after S. V. Kurashova
Email: info@eco-vector.com
Russian Federation
N. V. Fedorova
Department of Eye Diseases of the Kazan Order of the Red Banner of Labor of the Medical Institute named after S. V. Kurashova
Email: info@eco-vector.com
Russian Federation
References
Supplementary files