Stent retriever for iatrogenic cerebral thromboembolism treatment

Cover Page

Cite item

Full Text

Abstract

Thromboembolism is one of the dangerous complications of cerebrovascular endovascular surgeries, often resulting in severe disabilities. A clinical case of using stent retriever for treating iatrogenic cerebral thromboembolism occurred as a complication of diagnostic cerebral angiography is presented. Patient M., 49 years, was admitted in the department of neurology with referral diagnosis of subarachnoid hematoma. No pathologic changes of intracranial arteries were revealed on multi-spiral computed tomography, so cerebral angiography was administered. After administration of heparin (100 U/kg), selective cerebral angiography of all the intracranial vascular beds was performed using a diagnostic cerebral catheter with some technical difficulties. After the intervention was finished, the patient developed non-focal neurological symptoms, left-sided hemianopsia. Angiography of posterior circulation system was repeated immediately, left posterior cerebral artery occlusion was found. Stent retriever was used to restore the intracranial blood flow. An intracranial stent retriever Solitaire (EV3) was delivered to the occlusion and deployed with exposition of 5 minutes and further removal. Control angiography showed complete restoration of the intracranial blood flow without signs of distal embolism. The neurologic deficit had completely resolved during first 24 hours after the surgery. The presented clinical case illustrates the effect of stent retriever use to to restore the intracranial blood flow and stresses the need for such devices availability in departments performing cerebral surgeries in patients with cerebrovascular diseases.

About the authors

M U Volodyukhin

Interregional Clinical Diagnostic Center, Kazan, Russia; Kazan State Medical University, Kazan, Russia

Email: voloduckin@mail.ru

References

  1. Bracard S., Abdel-Kerim A., Thuillier L. et al. Endovascular coil occlusion of 152 middle cerebral artery aneurysms: initial and midterm angiographic and clinical results // J. Neurosurg. — 2010. — Vol 112. — P. 703–708.
  2. Connolly S., Rabinstein A., Carhuapoma R. Guidelines for the management of aneurysmal subarachnoid hemorrhage: a guideline for healthcare professionals from the American heart association/American stroke association // Stroke. — 2012. — Vol. 43. — P. 1711–1737.
  3. Connors J., Sacks D., Furlan A. et al. Training, competency, and credentialing standards for diagnostic сervicocerebral angiography, carotid stenting, and cerebrovascular intervention: a joint statement from the American academy of neurology, American association of neurological surgeons, American society of interventional and therapeutic radiology, American society of neuroradiology, congress of neurological surgeons, AANS/CNS cerebrovascular section, and society of interventional radiology // Radio­logy. — 2005. — Vol. 234. — P. 26–34.
  4. Costalat V., Machi P., Lobotesis K. et al. Rescue, combined, and stand-alone thrombectomy in the management of large vessel occlusion stroke using the solitaire device: a prospective 50-patient single-center study: timing, safety, and efficacy // Stroke. — 2011. — Vol. 42. — P. 1929–1935.
  5. Gonzalez F., Jabbour P., Tjoumakaris S. et al. Temporary endovascular bypass: rescue technique during mechanical thrombolysis // Neurosurgery. — 2012. — Vol. 70. — P. 245–252.
  6. Qureshi I., Luft R., Sharna M. et al. Prevention and treatment of tromboembolic and ischemic complications associated with endovascular procedures: Part I. Pathophysiological and pharmacological features // Neurosurgery. — 2000. — Vol. 46. — P. 1344–1359.

Supplementary files

Supplementary Files
Action
1. JATS XML

© 2014 Volodyukhin M.U.

Creative Commons License

This work is licensed
under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.





Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».