Modern Capabilities of Diagnostic Analytical Module "Verion Reference Unit" and Navigation System "Verion Digital Marker Microscope" in High-Tech Cataract and Presbyopia Surgery


Cite item

Full Text

Abstract

Aim - to show the possibilities of diagnostics with the use of VERION Measurement Module, followed by personalized drawing up an operation plan on the analytical module "VERION Vision Planner" and the calculation of high-tech IOLs. The evaluation of the work of the navigation system "VERION Digital Marker Microscope" in high-tech cataract surgery and presbyopia. Materials and methods. The results of the prospective open study of phacoemulsification of cataract and refractive lens surgery with implantation of high-tech intraocular lenses of Alcon company (USA) were studied. The calculation of the optical power of the IOL was performed using a navigation system, "VERION" (Alcon). Functional and refractive data before and after surgery were evaluated. Results. High-tech IOL implanted 100 patients (180 eyes). Sphericules clinical refraction was -0,15±0,28 diopters. Refraction of the target (em±0,5 DPT) was achieved in all patients. Intraoperative and postoperative complications were not observed. In all patients, the obtained refractive effect practically coincided with the potentially expected one. All patients are satisfied with the results of the operation and the choice of intraocular lens. Conclusion. 1. Diagnostic analytical module "VERION Reference Unit" of "VERION" system allows accurately selecting of the optical power of high-tech IOLs and their toric component with the preparation of the individual operation plan for each patient. 2. Navigation system "VERION Digital Marker Microscope" allows to carry out high-tech surgery of cataract and presbyopia according to the developed plan of operation. Deviation of the spherical refraction component obtained in the postoperative period from the expected, according to "VERION Vision Planner", was 0.2+0.15 DPTR; deviation of the cylindrical refraction component was 0.3+0.26 DPTR.

About the authors

IV V Malov

Samara State Medical University

Email: ivmsamara@gmail.com
PhD, Professor, head of Department of eye diseases of Samara State Medical University.

SD D Stebnev

«Eye Surgery» ophthalmologic clinic (Samara)

Email: stebnev2011@yandex.ru
PhD, Director of the eye clinic, "Eye Surgery" (Samara). кафедра глазных болезней ИПО СамГМУ, ул. Ташкентская, 159, г. Самара, Россия, 443095

VS S Stebnev

Samara State Medical University

Email: vision63@yandex.ru
PhD, associate Professor in the Department of eye diseases, Institute of Samara State Medical University.

References

  1. Першин К.Б., Пашинова Н.Ф., Цыганков А.Ю., Черкашина А.В. Первый опыт применения системы Verion при имплантации торических ИОЛупациентов с катарактой и астигматизмом в Российской Федерации. Катарактальная и рефракционная хирургия. 2016;16(1):20-24. 4
  2. Market Scope. Ophthalmic Market Perspectives. 2015. Marketscope LLC. (https://market-scope.com) Accessed July. 2016
  3. Cochener B, Vryghem J, Rozot P, Lesieur G. Visual and refractive outcomes after implantation of a fully diffractive trifocal lens. Clin Ophthalmol. 2012;(Vol. 6):1421 - 1427
  4. Mojzis P, Pena-Garcia P, Liehneova I, Ziak P Outcomes of a new diffractive trifocal intraocular lens. J Cataract Refract Surg. 2014;40:60-69
  5. Alcon Laboratory Notebook: 14073:77-78 3 PanOptix® Diffractive Optical Design. Alcon internal technical report: TDOC-0018723

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2018 Malov I.V., Stebnev S.D., Stebnev V.S.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).