Nuclear Magnetic Resonance Gyro: Ultimate Parameters
- Авторлар: Vershovskii A.K.1, Litmanovich Y.A.2, Pazgalev A.S.1, Peshekhonov V.G.2
-
Мекемелер:
- Ioffe Physical Technical Institute
- Concern CSRI Elektropribor
- Шығарылым: Том 9, № 3 (2018)
- Беттер: 162-176
- Бөлім: Article
- URL: https://bakhtiniada.ru/2075-1087/article/view/204414
- DOI: https://doi.org/10.1134/S2075108718030100
- ID: 204414
Дәйексөз келтіру
Аннотация
The fundamental limitations for the basic metrological parameters of the nuclear magnetic resonance gyro (NMRG) are analyzed. The determinant factors limiting its sensitivity, such as atomic projection noise and light shot noise, are considered. Formulas are derived to estimate the ultimate sensitivity of the NMRG and study its dependence on the parameters of the sensitive element. The main causes of NMRG drifts and possible ways to improve its metrological characteristics are discussed.
Авторлар туралы
A. Vershovskii
Ioffe Physical Technical Institute
Хат алмасуға жауапты Автор.
Email: antver@mail.ioffe.ru
Ресей, St. Petersburg
Yu. Litmanovich
Concern CSRI Elektropribor
Email: antver@mail.ioffe.ru
Ресей, St. Petersburg
A. Pazgalev
Ioffe Physical Technical Institute
Email: antver@mail.ioffe.ru
Ресей, St. Petersburg
V. Peshekhonov
Concern CSRI Elektropribor
Email: antver@mail.ioffe.ru
Ресей, St. Petersburg
Қосымша файлдар
