A Synchronous Machine with Abnormal Damper Winding Parameters


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Abstract—During the operation of synchronous explicit-pole machines, the damper winding failures can occur due to electromechanical and thermal effects on the elements upon a sudden short circuit of a stator winding, at frequent launches in the motoring mode, and at three-phase voltage unbalance. These effects can lead to damage to the contacts of rods of the damper winding with its short-circuiting rings and to the destruction of elements of the rings themselves. The defects can appear in a noticeable form only in the transient, asynchronous, and asymmetric modes. Based on a 2D analytical model of a synchronous explicit-pole machine in d, q coordinates, the rod currents and electromagnetic torque are analyzed in the asynchronous machine mode upon breakage of rods and interpole bridges near one or two poles of a damper winding. It has been concluded that the most dangerous anomaly of a damper winding is the breakage of interpole bridges near one or two poles, upon which high currents occur in rods and the electromagnetic torque is ten times higher than the nominal value.

作者简介

A. Afanasiev

Chuvash State University

编辑信件的主要联系方式.
Email: journal-elektrotechnika@mail.ru
俄罗斯联邦, Cheboksary, 428000

A. Afanasiev

Tupolev Kazan National Research Technical University

Email: journal-elektrotechnika@mail.ru
俄罗斯联邦, Kazan

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2019