Efficiency of a Claus furnace in the coke-oven gas desulphurization circuit of MMK


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The poor efficiency of the Claus furnace in sulfur removal at the coke plant of OAO Magnitogorskii Metallurgicheskii Kombinat (MMK) is analyzed on the basis of monitoring data for the sulfur recovery unit and thermodynamic calculations. The low level of sulfur removal from coke-oven gas (~60%) at OAO MMK is mainly due to thermodynamic limitations on the thermal stage of hydrogen-sulfide oxidation with the specific composition of the sour gas at coke plants: low hydrogen-sulfide concentration and combustion of the additional fuel (natural gas). With the kinetic constraints in the Claus furnace, the high CO2 content in the sour gas (up to 37 vol %) results in increased yield of carbonyl sulfide (~14%). That calls for particular care in optimizing the temperature during the catalytic stages and selecting the best catalysts.

作者简介

N. Gazimzyanov

OOO Verkhnevolzhskii Katalizatornyi Zavod Real Sorb

编辑信件的主要联系方式.
Email: ngazim@mail.ru
俄罗斯联邦, Yaroslavl

O. Platonov

OOO Verkhnevolzhskii Katalizatornyi Zavod Real Sorb

Email: ngazim@mail.ru
俄罗斯联邦, Yaroslavl

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2017