The Influence of Voltage Polarity on the Regime of Atmospheric-Pressure Glow Discharge Operation in Flows of Atomic and Molecular Gases


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Electrical characteristics of atmospheric-pressure glow discharge at constant currents up to 40 mA in flows of atomic and molecular gases have been measured at volume flow rates varied within 0.5–5 L/min. It was found that the voltage drop on the discharge gap in molecular gases depends not only on the flow rate, but also on the polarity of applied voltage. As the gas flow rate increases, the discharge operation in oxygen and nitrogen becomes unstable and the voltage drop on discharge gap increases by several hundred volts. Both these effects are manifested much more strongly for a positive discharge voltage than for the negative voltage. In helium and argon flowing at a preset rate, the voltage polarity on electrodes does not influence the regime of discharge operation.

作者简介

A. Astaf’ev

Institute for Electrophysics and Electric Power, Russian Academy of Sciences

编辑信件的主要联系方式.
Email: astafev-aleksandr@yandex.ru
俄罗斯联邦, St. Petersburg, 191186

O. Stepanova

St. Petersburg State University

Email: astafev-aleksandr@yandex.ru
俄罗斯联邦, St. Petersburg, 199034

M. Pinchuk

Institute for Electrophysics and Electric Power, Russian Academy of Sciences

Email: astafev-aleksandr@yandex.ru
俄罗斯联邦, St. Petersburg, 191186

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2019