Cleaning air from multicomponent impurities of volatile organic compounds by pulsed corona discharge


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The relative efficiency of the removal of impurities from airflow under the action of pulsed corona discharge has been studied by processing model mixtures of air with volatile organic compounds (VOCs). A method is proposed that allows the influence of the VOC structure on its reactivity to be directly determined. For this purpose, it is suggested to calculate a relative energy parameter characterizing the reactivity of a given impurity component in the framework of the method employed. This approach significantly intensifies the process of determination of the energy parameters of impurity removal and can be used as a criterion for comparative estimation of the efficiency of various methods employing nonequilibrium plasma for cleaning air from VOCs.