Specifics of Preparation of Storage Chambers for Ultracold Neutrons and EDM Spectrometer Sensitivity


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Storage cells for ultracold neutrons (UCNs) are crucial parts of the experimental setup used to measure the electric dipole moment (EDM) of a neutron. The effect of the technology of preparation and sputtering of elements of UCN storage cells on the limiting operating voltage and on the capacity of these cells for long-term operation under high voltage with polarity switching was studied. A voltage magnitude of ±250 kV was obtained in tests of a neutron storage cell for the EDM spectrometer with a cell height of 9 cm.

作者简介

M. Lasakov

Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute

Email: pirozhkov_an@pnpi.nrcki.ru
俄罗斯联邦, Gatchina, Leningrad oblast, 188300

A. Pirozhkov

Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute

编辑信件的主要联系方式.
Email: pirozhkov_an@pnpi.nrcki.ru
俄罗斯联邦, Gatchina, Leningrad oblast, 188300

A. Serebrov

Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute

Email: pirozhkov_an@pnpi.nrcki.ru
俄罗斯联邦, Gatchina, Leningrad oblast, 188300

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2019