Coefficient of the Performance of a Segmented Thermoelectric Cooling Leg

Abstract

One of the main energy characteristics of a cooling leg is the maximum available temperature difference (ΔTmax). Its increase indicates an increase in the coefficient of performance (COP) at all temperatures. The use of a segmented leg makes it possible to increase the ΔTmax value; however, the maximum available COP increases only at large temperature differences, whereas at small temperature differences the maximum available COP is even smaller than in a simple leg.

About the authors

I. A. Drabkin

RMT Ltd.

Author for correspondence.
Email: igordrabk@gmail.com
Russian Federation, Moscow, 115230