Techniques for Final Pelvic Ring Fixation Based on the Method of Finite Element Modeling
- 作者: Donchenko S.V1, Dubrov V.E2, Golubyatnikov A.V3, Chernyaev A.V1, Kuz’kin I.A3, Alekseev D.V1, Lebedev A.F1
 - 
							隶属关系: 
							
- City Clinical Hospital named after S.P. Botkin, Moscow
 - Moscow State University named after M.V. Lomonosov, Moscow
 - Company OOO «Kheksa», Moscow, Russia
 
 - 期: 卷 21, 编号 1 (2014)
 - 页面: 38-44
 - 栏目: Articles
 - URL: https://bakhtiniada.ru/0869-8678/article/view/47566
 - DOI: https://doi.org/10.17816/vto20140138-44
 - ID: 47566
 
如何引用文章
全文:
详细
作者简介
S. Donchenko
City Clinical Hospital named after S.P. Botkin, Moscow
														Email: don_03@mail.ru
				                					                																			                								канд. мед. наук, зав. отделением травматологии №27 ГКБ им. С.П. Боткина; Тел.: +7 (916) 196-79-42				                								125284, Москва, 2-й Боткинский проезд, д. 5						
V. Dubrov
Moscow State University named after M.V. Lomonosov, Moscowдоктор мед. наук, зав. кафедрой общей и специализированной хирургии ФФМ МГУ
A. Golubyatnikov
Company OOO «Kheksa», Moscow, Russiaгенеральный директор компании ООО «ХЕКСА»
A. Chernyaev
City Clinical Hospital named after S.P. Botkin, Moscowканд. мед. наук, врач травматолог-ортопед отделения травматологии №27 ГКБ им. С.П. Боткина
I. Kuz’kin
Company OOO «Kheksa», Moscow, Russia
														Email: info@hexa.ru
				                					                																			                								инженер-конструктор ООО «ХЕКСА»; http://www.hexa.ru. Тел.: +7 (495) 632-24-63				                								105082, Москва, Чешихинский пр-д, д.18/20, стр. 1, ООО «Хекса»						
D. Alekseev
City Clinical Hospital named after S.P. Botkin, Moscowврач травматолог-ортопед отделения травматологии №27 ГКБ им. С.П. Боткина
A. Lebedev
City Clinical Hospital named after S.P. Botkin, Moscowврач травматолог-ортопед отделения травматологии №27 ГКБ им. С.П. Боткина
参考
- Papathanasopoulos A., Tzioupis C., Giannoudis V.P., Roberts C., Giannoudis P.V. Biomechanical aspects of pelvic ring reconstruction techniques: Evidence today. Injury. 2010; 41 (12): 1220-7.
 - Vigdorchik J.M., Esquivel A.O., Jin X., Yang K.H., Onwudiwe N.A., Vaidya R. Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically un- stable pelvic fractures. J. Orthop. Surg. Res. 2012; 7: 31.
 - Grimshaw C.S., Bledsoe J.G., Moed B.R. Locked versus standard unlocked plating of the pubic symphysis: a cadaver biomechanical study. J. Orthop. Trauma. 2012; 26: 402-6.
 - Pizanis A., Garcia P., Santelmann M., Culemann U., Pohlemann T. Reduction and fixation capabilities of dif- ferent plate designs for pubic symphysis disruption: A biomechanical comparison. Injury. 2013; 44 (2): 183-8.
 - Dickson K.F., Matta J.M. Skeletal deformity after anterior external fixation of the pelvis. J. Orthop. Trauma. 2009; 23 (5): 327-32.
 - Zhao Y., Li J., Wang D., Liu Y., Tan J., Zhang S. Comparison of stability of two kinds of sacroiliac screws in the fixation of bilateral sacral fractures in a finite element model. Injury. 2012; 43: 490-4.
 - Eichenseer P.H., Sybert D.R., Cotton J.R. A finite element analysis of sacroiliac joint ligaments in response to different loading conditions. Spine. 2011; 36: E1446-52.
 - Kobbe P., Hockertz I., Sellei R.M., Reilmann H., Hockertz T. Minimally invasive stabilisation of posterior pelvic-ring instabilities with a transiliac locked compression plate. Int. Orthop. 2012; 36: 159-64.
 - Cimerman M., Kristan A. Preoperative planning in pelvic and acetabular surgery: The value of advanced computerized planning modules Injury. 2007; 38: 442-9.
 - Dujardin F.H., Roussignol X., Hossenbaccus M., Thomine J.M. Experimental study of the sacroiliac joint micromotion in pelvic disruption. J. Orthop. Trauma. 2002; 16 (2): 99-103.
 - Doro C.J., Forward D.P., Kim H., Nascone J.W., Sciad ni M.F., Adam H. et al. Does 2.5 cm of symphyseal widening differentiate anteroposterior compression I from anteroposterior compression II pelvic ring injuries. J. Orthop. Trauma. 2010; 24: 610-5.
 - Pelvis. J. Orthop. Trauma. 2007; 21 (Suppl.): S59-67.
 - McCormack R., Strauss E.J., Alwattar B.J., Tejwani N.C. Diagnosis and management of pelvic fractures. Bull. NYU Hosp. Jt Dis. 2010; 68(4): 281-91.
 - Burgess A.R., Eastridge B.J., Young J.W., Ellison T.S., Ellison P.S. Jr., Poka A. et al. Pelvic ring disruptions: effective classification system and treatment protocols. J. Trauma. 1990; 30 (7): 848-56.
 - Gabbe B.J., Esser M., Bucknill A., Russ M.K., Hofstee D-J., Cameron P.A. et al. The imaging and classification of severe pelvic ring fractures Experiences from two level 1 trauma centres. Bone Joint J. 2013; 95-B: 1396-1401.
 - Zhao Y., Li J., Wang D., Lian W. Parameters of lengthened sacroiliac screw fixation: a radiological anatomy study. Eur. Spine J. 2012; 21: 1807-14.
 - Cano-Luis P., Giraldez-Sanchez M.A., Martinez-Reina J., Serrano-Escalante F.J., Galleguillos-Rioboo C., Lazaro-Gonzalvez A. et al. Biomechanical analysis of a new minimally invasive system for osteosynthesis of pubis symphysis disruption. Injury. 2012; 43 Suppl 2: S20-7.
 - Moed B.R., Grimshaw C.S., Segina D.N. Failure of locked design-specific plate fixation of the pubic symphysis: a report of six cases. J. Orthop. Trauma. 2012; 26 (7): e71-5.
 - van Zwienen C.M., van den Bosch E.W., Snijders C.J., Kleinrensink G.J., van Vugt A.B. Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. J. Orthop. Trauma. 2004; 18 (9): 589-95.
 - Gardner M.J., Routt M.L. Jr. The antishock iliosacral screw. J. Orthop. Trauma. 2010; 24: e86-9.
 - Emohare O., Slinkard N., Lafferty P., Vang S., Morgan R. The effect of early operative stabilization on late displacement of zone I and II sacral fractures. Injury. 2013; 44 (2): 199-202.
 - Calafi L.A., Routt M.L. Jr. Posterior iliac crescent fracture-dislocation: What morphological variations are amenable to iliosacral screw fixation? Injury. 2013; 44 (2): 194-8.
 - Yinger K., Scalise J., Olson S.A., Bay B.K., Finkemeier C.G. Biomechanical comparison of posterior pelvic ring fixation. J. Orthop. Trauma. 2003; 17 (7): 481-7.
 - Донченко С.В., Дубров В.Э., Слиняков Л.Ю., Черняев А.В., Лебедев А.Ф., Алексеев Д.В. Алгоритм хирургического лечения нестабильных повреждений тазового кольца. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2013; 4: 9-16.
 
补充文件
				
			
						
						
					
				