Hip Joint Arthrodesis by Rod Device
- Authors: Zhadyonov I.I.1, Zuev P.A.1, Muromtsev V.A.1
-
Affiliations:
- Republican Arthrology Center at Saratov Institute of Traumatology and Orthopedics
- Issue: Vol 5, No 2 (1998)
- Pages: 43-46
- Section: Articles
- URL: https://bakhtiniada.ru/0869-8678/article/view/104490
- DOI: https://doi.org/10.17816/vto104490
- ID: 104490
Cite item
Full Text
Abstract
Authors elaborated and introduced into clinical practice the method of controlled hip joint arthrodesis using the rod device for fixation. The proposed method not only allowed to activate patients earlier but also relieved their self-service and enabled the surgeon to influence the bone tissue reparative regeneration at all stages of postoperative management. 63 patients with different hip joint pathology were operated on. In 57 cases ankylosis was achieved in 5-12 months after operation.
Full Text
##article.viewOnOriginalSite##About the authors
I. I. Zhadyonov
Republican Arthrology Center at Saratov Institute of Traumatology and Orthopedics
Author for correspondence.
Email: info@eco-vector.com
Russian Federation, Saratov
P. A. Zuev
Republican Arthrology Center at Saratov Institute of Traumatology and Orthopedics
Email: info@eco-vector.com
Russian Federation, Saratov
V. A. Muromtsev
Republican Arthrology Center at Saratov Institute of Traumatology and Orthopedics
Email: info@eco-vector.com
Russian Federation, Saratov
References
Supplementary files