Use of the standing wave method to study seismically insulated buildings


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

The use of the standing wave method to study seismically insulated buildings is substantiated. For two buildings of interest with different types of seismic protection (a “flexible” floor and rubber base insulators), the total field of standing waves is studied in detail. Effects that raise doubts about the reliability of seismic protection are found. Estimation of the role of nonlinear vibrations in standing waves has made it possible to establish that weak nonlinearity is recorded at high-frequency modes at small vibration amplitudes, due to discordant vibrations of the building components. The data obtained by the standing wave method are recommended for verifying models used to calculate seismic insulation of buildings.

Авторлар туралы

A. Emanov

Altay-Sayan Division, Geophysic Survey, Siberian Branch; Institute of Petroleum Geology and Geophysics, Siberian Branch; Novosibirsk National Research State University

Хат алмасуға жауапты Автор.
Email: emanov@gs.nsc.ru
Ресей, pr. Akademika Koptyuga 3, Novosibirsk, 630090; pr. Akademika Koptyuga 3, Novosibirsk, 630090; ul. Pirogova 2, Novosibirsk, 630090

A. Krasnikov

Altay-Sayan Division, Geophysic Survey, Siberian Branch

Email: emanov@gs.nsc.ru
Ресей, pr. Akademika Koptyuga 3, Novosibirsk, 630090

Қосымша файлдар

Қосымша файлдар
Әрекет
1. JATS XML

© Allerton Press, Inc., 2016