Condensation heat transfer of pure steam and steam from gas–steam mixture in tubes of AES-2006 PHRS SG heat exchanger


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Results of experimental determination of the average heat transfer coefficient upon condensation of pure steam αc and steam from air–steam mixture αas.m in tubes of a large-scale model of the emergency cooling heat exchanger in the system of passive heat removal through steam generators of AES-2006 project at Leningrad II NPP are presented. The model contained 16 parallel tubes with a diameter of 16 × 2 mm and a length of 2.9 m connected to the upper steam distributing and lower condensate gathering horizontal collectors; the distance between their axes was 2.28 m. The tube segments were vertical, horizontal, or inclined. The internal diameter of the collectors was 40 or 60 mm. The model was placed in the lower part of a tank with a height of 6.5 m and a volume of 5.85 m3 filled with boiling water at atmospheric pressure. The experimental parameters were as follows: pressure range 0.43–7.77 MPa, condensate Reynolds number Ref = (0.87–9.3) × 103, and average air volume fraction at the segment with air–steam mixture 0.18–0.85. The studies showed that nonuniformity of static pressure distribution along the steam-distributing collector strongly influences the reduction of αc value (ejecting effect). The agreement between experimental and calculated according to statutory guidelines values of αc for vertical tubes is achieved if the dynamic head of the steam flow at the input of the steam-distributing collector does not exceed 1 kPa. Equations for calculation of the diffusion heat transfer coefficient at steam condensation from the air–steam mixture αas.m on the internal tube surface are proposed. In the considered conditions, air is completely displaced by steam flow from the upper to the lower part of the tubes. The boundary between these regions is characterized by an average reduced steam velocity through this cross section of 1.6 ± 0.4 m/s. Above the boundary cross section, it is recommended to calculate αc. according to [1].

作者简介

A. Shcheglov

OAO Polzunov Scientific and Development Association on Research and Design of Power Equipment

Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 191167

V. Lychakov

OAO Polzunov Scientific and Development Association on Research and Design of Power Equipment

Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 191167

S. Alekseev

OAO ATOMPROEKT Scientific Research and Design Construction Institute of Power Technologies

Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 197183

V. Kuhtevich

OAO ATOMPROEKT Scientific Research and Design Construction Institute of Power Technologies

Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 197183

S. Svetlov

OAO ATOMPROEKT Scientific Research and Design Construction Institute of Power Technologies

Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 197183

V. Sidorov

OAO ATOMPROEKT Scientific Research and Design Construction Institute of Power Technologies

Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 197183

B. Balunov

OAO Polzunov Scientific and Development Association on Research and Design of Power Equipment

编辑信件的主要联系方式.
Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 191167

V. Il’in

OAO Polzunov Scientific and Development Association on Research and Design of Power Equipment

Email: balunov.ckti@mail.ru
俄罗斯联邦, St. Petersburg, 191167

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Inc., 2017