Implantation of the paclitaxel-eluting stent Apollo in patients with stable angina pectoris: Long-term angiographic and clinical results

  • 作者: Batyraliev TA1, Fetser DV2, Samko AN3, Sidorenko BA4
  • 隶属关系:
    1. Sani Konukogly Medical Center, Gaziantep, Turkey
    2. Regional Clinical Hospital Hospital, Lipetsk
    3. A. L. Myasnikov Institute of Clinical Cardiology, Russian Cardiology Research-and-Production Complex, Russian Agency for Medical Technologies, Moscow
    4. Training and Research Center, Department for Presidential Affairs of the Russian Federation, Moscow
  • 期: 卷 82, 编号 8 (2010)
  • 页面: 20-23
  • 栏目: Editorial
  • URL: https://bakhtiniada.ru/0040-3660/article/view/30615
  • ID: 30615

如何引用文章

全文:

详细

Aim: to assess the long-term angiographic and clinical results of percutaneous coronary interventions (PCI) with implantation of the drug-eluting stent (DES) Apollo in patients with stable angina pectoris.
Subjects and methods. The study enrolled 48 patients with stable angina who had been implanted with 59 stents. A follow-up of the patients lasted 12 months.
Results. The intervention was successful in 100% patients. Following 12 months, 81.3% of the patients underwent angiography that demonstrated that the vascular diameter decreased by 0.32±0.45 mm and the rate of restenosis was reduced by only 5.3%. The frequency of evident cardiac complications over 12 months was as high as 11.6%.
Conclusion. The DES Apollo provides a way of safely performing PCI, by achieving a high of angiographic success rate. The application of this stent yields long-term good angiographic and clinical results in patients with stable angina pectoris.

作者简介

T Batyraliev

Sani Konukogly Medical Center, Gaziantep, Turkey

Email: talantbekb@yahoo,com
Sani Konukogly Medical Center, Gaziantep, Turkey

D Fetser

Regional Clinical Hospital Hospital, Lipetsk

Email: fettser@gmail.com
Regional Clinical Hospital Hospital, Lipetsk

A Samko

A. L. Myasnikov Institute of Clinical Cardiology, Russian Cardiology Research-and-Production Complex, Russian Agency for Medical Technologies, Moscow

Email: samkoan@mail.ru
A. L. Myasnikov Institute of Clinical Cardiology, Russian Cardiology Research-and-Production Complex, Russian Agency for Medical Technologies, Moscow

B Sidorenko

Training and Research Center, Department for Presidential Affairs of the Russian Federation, Moscow

Email: sid_b_a@mail.ru
Training and Research Center, Department for Presidential Affairs of the Russian Federation, Moscow

参考

  1. Беленков Ю. Н. Лечение ишемической болезни сердца: старые традиции и новые тенденции. Тер. арх. 2005; 9: 5- 8.
  2. Sigwart U., Puel J., Mirkovitch V. et al. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N. Engl. J. Med. 1987; 316: 701-706.
  3. Radke P. W., Kaiser A., Frost C., Sigwart U. Outcome after treatment of coronary in-stent restenosis; results from a systematic review using meta-analysis techniques. Eur. Heart J. 2003; 24: 266-273.
  4. Lowe H. C., Oesterle S. N., Khachigian L. M. Coronary in-stent restenosis: current status and future strategies. J. Am. Coll. Cardiol. 2002; 39: 183-193.
  5. Жамгыргиев Ш. Т., Фетцер Д. В., Першуков И. В. и др. Клиническое значение стентов с лекарственным покрытием. Тер. арх. 2007; 9: 79-84.
  6. Kastrati A., Dibra A., Eberle S., et al. Sirolimus-eluting stents vs paclitaxel-eluting stents in patients with coronary artery disease: meta-analysis of randomized trials. J. A. M. A. 2005; 294: 819-825.
  7. Bokeriya L. A., Sengul H., Guseyinov E. A. et al. Stents which are used with polymer technology and bioabsobable stents. Turk. J. Invest. Cardiol. 2007; 11: 156-162.
  8. Babapulle M. N., Joseph L., Belisle P. et al. A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents. Lancet 2004; 364: 583-591.
  9. Kotani J., Awata M., Nanto S. et al. Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic ?ndings. J. Am. Coll. Cardiol. 2006; 47: 2108-2111.
  10. Wessely R., Kastrati A., Sch?mig A. Late restenosis in patients receiving a polymer coated sirolimus-eluting stent. Ann. Intern. Med. 2005; 143: 392-394.
  11. Joner M., Finn A. V., Farb A. et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J. Am. Coll. Cardiol. 2006; 48: 193-202.
  12. Psterer M., Brunner-La Rocca H. P., Buser P. T. et al. BASKET investigators. Late clinical events after clopidogrel discontinuation may limit the bene?t of drug-eluting stents. J. Am. Coll. Cardiol. 2006; 48: 2584-2591.
  13. King S. B., Aversano T., Ballard W. L. et al. ACCF/AHA/ SCAI 2007 update of the clinical competence statement on cardiac interventional procedures. Circulation 2007; 116: 98- 124.
  14. Serruys P. W., Kutryk M. J. B. Handbook of coronary stents. 3-rd ed. London: Martin Dunitz; 2000.
  15. Батыралиев Т. А., Фетцер Д. В., Преображенский Д. В., Сидоренко Б. А. Проблема осложнений при чрескожных коронарных вмешательствах. Часть I. Характер и частота осложнений. Кардиология 2008; 48 (1): 81-87.
  16. Sigwart U., Urban P., Golf S. et al. Emergency stenting for acute occlusion after coronary balloon angioplasty. Circulation 1988; 78: 1121-1127.
  17. Serruys P. W., de Jaegere P., Kiemeneij F. et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease: Benestent Study Group. N. Engl. J. Med. 1994; 331: 489-495.
  18. Baim D. S., Levine M. J., Leon M. B. et al. Management of restenosis within the Palmaz-Schatz coronary stent: the U. S. multicenter experience - the U. S. Palmaz-Schatz Stent Investigators. Am. J. Cardiol. 1993; 71: 364-366.
  19. Antoniucci D., Bartorelli A., Valenti R. et al. Clinical and angiographic outcome after coronary arterial stenting with the carbostent. Am. J. Cardiol. 2000; 85: 821-825.
  20. Boland J. L., Corbeij H., Van Der Giessen W. et al. Multicenter evaluation of the phosphorylcholinecoated biodivYsio stent in short de novo coronary lesions: The SOPHOS study. Int. J. Cardiovasc. Intervent. 2000; 3: 215--225.
  21. Guarda E., Marchant E., Fajuri A. et al. Oral rapamycin to prevent human coronary stent restenosis: A pilot study. Am. Heart J. 2004; 148(2): e9.
  22. Takagi T., Akasaka T., Yamamuro A. et al. Troglitazone reduces neointimal tissue proliferation after coronary stent implantation in patients with noninsulin dependent diabetes mellitus. J. Am. Coll. Cardiol. 2000; 36: 1529-1535.
  23. Holmes D., Fitzgerald P., Goldberg S. et al. The PRESTO (Prevention of Restenosis with Tranilast and its Outcomes) protocol: a double-blind, placebo-controlled trial. Am. Heart J. 2000; 139: 23-31.
  24. Dobesh P. P., Stacy Z. A., Ansara A. J. et al. Drug-eluting stents: A mechanical and pharmacologic approach to coronary artery disease. Pharmacotherapy 2004; 24 (11): 1554-1577.
  25. Sasseen B., Costa M. A. A new stent revolution: Drug-eluting stents. In: American college of cardiology. 52nd Annual scientific session. Chicago; 2003.
  26. Батыралиев Т. А., Першуков И. В. Обзор клинических исследований по ишемической болезни сердца и ее инвазивному лечению. Кардиология 2002; 5: 68-70.
  27. Rensing B. J., Vos J., Smits P. C. et al. Coronary restenosis elimination with a sirolimus eluting stent. First European human experience with 6-month angiographic and intravascular ultrasonic follow-up. Eur. Heart J. 2001; 22: 2125-2130.
  28. Ellis S. G., Popma J. J., Lasala J. M. et al. Relationship between angiographic late loss and target lesion revascularization after coronary stentimplantation: analysis from the TAXUS-IV trial. J. Am. Coll. Cardiol. 2005; 45: 1193-1200.
  29. Windecker S., Remondino A., Eberli F. R. et al. Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization. N. Engl. J. Med. 2005; 353: 653-662.
  30. Dibra A., Kastrati A., Mehilli J. et al. Paclitaxel-eluting stents compared with sirolimus-eluting stents for the prevention of restenosis in diabetic patients with coronary artery disease. N. Engl. J. Med. 2005; 353: 663-670.
  31. Sousa J. E., Costa M. A., Abizaid A. et al. Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents. Circulation 2005; 111: 2326-2329.
  32. Hermiller J. B., Raizner A., Cannon L. et al. Outcomes with the polymer-based paclitaxel-eluting TAXUS stent in patients with diabetes mellitus: the TAXUS-IV trial. J. Am. Coll. Cardiol. 2005; 45: 1172-1179.
  33. Abizaid A., Costa M. A., Blanchard D. et al. Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients. Insights from the RAVEL Trial. Eur. Heart J. 2004; 25: 107- 112.
  34. Schofer J., Schluter M., Gershlick A. H. et al. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet 2003; 362: 1093-1099.

补充文件

附件文件
动作
1. JATS XML

版权所有 © Consilium Medicum, 2010

Creative Commons License
此作品已接受知识共享署名-非商业性使用-相同方式共享 4.0国际许可协议的许可。
 
 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».