The Long-Term Stability of a Fused-Silica Proportional Counter


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The long-term stability of the counting and spectrometric characteristics of a fused silica proportional counter has been investigated to assess its applicability to search for an admixture of sterile neutrinos. The results of continuous measurements of the K-peak position in the spectrum of deposited energies from decay of 37Ar traces in a counter filled with CO2 are presented. It is shown that the gas amplification remained stable within 0.1% during 1 month of continuous measurements at an initial isotope activity of approximately 100 Bq. This estimate of the stability of a fused silica counter is 5 times better than the values published earlier.

Sobre autores

D. Abdurashitov

Institute for Nuclear Research, Russian Academy of Sciences

Autor responsável pela correspondência
Email: jna@inr.ru
Rússia, Moscow, 117312

V. Chernov

Institute for Nuclear Research, Russian Academy of Sciences

Email: jna@inr.ru
Rússia, Moscow, 117312

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Pleiades Publishing, Inc., 2018