A Ring Neutron Detector for a Time-of-flight Diffractometer Based on Linear Scintillation Detectors with Silicon Photomultipliers


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A ring neutron detector has been developed for a time-of-flight diffractometer based on linear scintillation detectors. Light is transported over an organic glass light guide with a diffuse reflector. This scheme makes it possible to collect more photons than are collected in detectors based on wavelength-shifting fibers and to use avalanche photodiodes (SiPMs) instead of photomultiplier tubes. Testing confirmed that these detectors could be used as an alternative for widely used proportional neutron counters filled with 3He.