Peculiarities of Thermophysical Processes of “Wet Compression” in Power Units with Highly Atomized Water Injection and Their Influence on Power Units Operation


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Gas-turbine units (with finely atomized water being injected into compressor) characteristics are discussed. Turbo-compressor group rotational speed variation and other factors are taken into account for twin-shaft units. Calculations were based on the mathematic model, which was verified by test results obtained at experimental Institute for High Temperatures unit GTU-1500 with twin-shaft engine (ТV3-117).