Ignition of a two-fuel hydrogen–silane mixture in air
- Authors: Tropin D.A.1, Fedorov A.V.1
-
Affiliations:
- Khristianovich Institute of Theoretical and Applied Mechanics, Siberian Branch
- Issue: Vol 53, No 1 (2017)
- Pages: 1-7
- Section: Article
- URL: https://bakhtiniada.ru/0010-5082/article/view/152711
- DOI: https://doi.org/10.1134/S0010508217010014
- ID: 152711
Cite item
Abstract
Based on the previously developed model of detailed kinetics, the ignition delay time of two-fuel hydrogen–silane–air mixtures is calculated. The effect of the silane concentration and the temperature of the mixture on the ignition delay time is determined. It is shown that addition of a small (within 20%) amount of silane to the hydrogen–air mixture in the temperature range from 1200 to 2500 K leads to significant reduction of the ignition delay time of the mixture, whereas there is only a minor decrease in mixtures with silane concentrations higher than 20%.
About the authors
D. A. Tropin
Khristianovich Institute of Theoretical and Applied Mechanics, Siberian Branch
Author for correspondence.
Email: d.a.tropin@itam.nsc.ru
Russian Federation, Novosibirsk, 630090
A. V. Fedorov
Khristianovich Institute of Theoretical and Applied Mechanics, Siberian Branch
Email: d.a.tropin@itam.nsc.ru
Russian Federation, Novosibirsk, 630090
Supplementary files