Visual acuity at intermediate distances after implantation of different models of intraocular lenses

Cover Page

Cite item

Full Text

Abstract

Aim. To study the rehabilitative effect of treatment of cataracts by implanting trifocal refractive-diffractive soft intraocular lens MIOL-Record 3. Methods. 192 patients (216 eyes) who were operated on for cataract participated in the study. The first (main) group included 63 patients (72 eyes) in whom cataract extraction and implantation of the domestic trifocal refractive-diffractive monolithic (soft) intraocular lens MIOL-Record 3 was performed. The second group included 64 patients (70 eyes) in whom cataract extraction and implantation of the domestic bifocal refractive-diffractive lens MIOL-Accord was performed. The third group consisted of 65 patients (74 eyes) in whom cataract extraction and implantation of the domestic monofocal lens MIOL-2 was performed. Preoperative examination was performed the day before surgery, postoperative - after 7 days, 1, 3, 6 and 12 months. Results. The mean value of visual acuity at a distance of 50 cm without correction in the group of patients with MIOL-Record 3 1 month after surgery was 0.42±0.01 and was significantly higher than such in patients with MIOL-Accord and MIOL-2 - 0.14±0.01 and 0.1±0.001, respectively. A questionnaire survey revealed that in the group with MIOL-Record 3 additional correction with glasses is never used at the intermediate distance in 98.62% of the cases, in groups with MIOL-Accord - in 54.28%, and with MIOL-2 - in 25.68% of cases. Patients with MIOL-Record 3 were completely satisfied with the results of surgery in 70.84% of the cases, and in groups with MIOL-Accord and MIOL-2 - in 54.28, and 27.03% of cases, respectively. Conclusion. The conducted studies have established the best rehabilitative effect of the treatment of cataract during implantation of a trifocal refractive-diffractive intraocular lens MIOL-Record 3.

About the authors

A D Chuprov

Kirov Clinical Ophthalmology Hospital, Kirov, Russia; Kirov State Medical Academy, Kirov, Russia

K S Ivonin

Kirov Clinical Ophthalmology Hospital, Kirov, Russia

Email: doctor_ivonin@mail.ru

A A Zamyrov

Kirov Clinical Ophthalmology Hospital, Kirov, Russia

Yu V Kudryavtseva

Kirov Clinical Ophthalmology Hospital, Kirov, Russia; Kirov State Medical Academy, Kirov, Russia

References

  1. Аветисов С.Э., Егорова Е.А., Мошетова Л.К. и др. Офтальмология: национальное руководство. - М.: ГЭОТАР-Медиа, 2008. - 944 с.
  2. Коронкевич В.П., Ленкова Г.Н., Корольков В.П. Бифокальная интраокулярная линза вместо хрусталика // ФОТОНИКА. - 2008. - №1. - С. 10-13.
  3. Тахтаев Ю.В., Балашевич Л.И. Первый опыт клинического применения мультифокальных интраокулярных линз AcrySof Restor // Офтальмохирургия. - 2004. - №3. - С. 30-34.
  4. Треушников В.М., Чередник В.И. Первая трифокальная интраокулярная линза // Визит к офтальм. - 2007. - №9. - С. 2-17.
  5. Fraco P.H. Postoperative deposits on the AcrySof intraocular lens // Austral. and N. Zealand J. of Ophthalm. - 1999. - Vol. 27, N 5. - P. 301.
  6. Gatinel D., Pagnoulle C., Houbrechts Y. Design and qualification of a diffractive trifocal optical profile for intraocular lenses // J. Cataract. Refract. Surg. - 2011. - Vol. 37, N 11. - P. 2060-2067.
  7. Hoffmann M.B., Spors F., Langenbucher A. et al. Minor effect of blue-light filtering on multifocal electroretinograms // J. Cataract. Refract. Surg. - 2010. - Vol. 36, N 10. - P. 1692-1699.
  8. Lubiński W., Gronkowska-Serafin J., Podboraczyńska-Jodko K. et al. Cataract surgery with bilateral multifocal ReZoom intraocular lens implant ation--comparison of 3 and 12 month follow-up // Klinika Oczna. - 2009. - Vol. 111. - P. 327-331.
  9. Madrid-Costa D., Cerviño A., Ferrer-Blasco T. et al. Visual and optical performance with hybrid multifocal intraocular lenses // Clin. Exp. Optom. - 2010. - Vol. 93, N 6. - P. 426-440.

Supplementary files

Supplementary Files
Action
1. JATS XML

© 2012 Chuprov A.D., Ivonin K.S., Zamyrov A.A., Kudryavtseva Y.V.

Creative Commons License

This work is licensed
under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.





Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».