Resumo

The results of study of a fiber-optic gyroscope prototype with 0.01–0.001deg/h drift are presented. The gyroscope comprises three feedback loops: one for Sagnac phase difference compensation, the second one for the scale factor stabilization, and the third (fast-response) one for the compensation of constant component of optical signal on the photodetector, affecting the measurement channel. To increase the accuracy of the prototype gyroscope up to the level of 0.001 deg/h, it is proposed to use the fourth and the fifth feedback loops which will suppress the parasitic effects in the integrated optic phase modulators.