Evaluating the Selection of a Booster Pump on the Suction Line of a Floating Dredge
- 作者: Aref’ev N.N.1
-
隶属关系:
- Volga State University of Water Transport
- 期: 卷 51, 编号 5 (2018)
- 页面: 532-535
- 栏目: Article
- URL: https://bakhtiniada.ru/1570-145X/article/view/245934
- DOI: https://doi.org/10.1007/s10749-018-0868-6
- ID: 245934
如何引用文章
详细
Approaches to the prevention of cavitation in a soil pump at high soil intake rates are analyzed. It is shown that installation of an additional (booster) pump in the underwater part of a suction-type hydraulic-fill pipeline is an optimal approach. As a result of calculations it is found that axial- and diagonal-type booster pumps possess the best energy indicators.
作者简介
N. Aref’ev
Volga State University of Water Transport
编辑信件的主要联系方式.
Email: Arefyev1987@gmail.com
俄罗斯联邦, Perm
补充文件
