Aspects of the Thermal Performance of a Cupola with a Closed Top for Remelting Mineral-Bearing Raw Materials
- Авторы: Matyukhin V.I.1, Matyukhin O.V.1, Matyukhina A.V.1
-
Учреждения:
- Ural Federal University
- Выпуск: Том 56, № 5 (2016)
- Страницы: 465-469
- Раздел: Heat Engineering
- URL: https://bakhtiniada.ru/1083-4877/article/view/247906
- DOI: https://doi.org/10.1007/s11148-016-9870-4
- ID: 247906
Цитировать
Аннотация
The design features and operating parameters of a cupola-based equipment complex developed by the Italian company “Gamma Meccanica” are analyzed in connection with the increasing use of this equipment in the production of heat-insulating mineral-wool products. The limitations of the injection system are discussed and it shown that the main physico-chemical, gasdynamic, and thermal processes which take place are quite nonuniform, which restricts the maximum productivity of the complex to 6 tons/h and limits its overall thermal efficiency to 11.78%.
Об авторах
V. Matyukhin
Ural Federal University
Автор, ответственный за переписку.
Email: matyhin53@mail.ru
Россия, Ekaterinburg
O. Matyukhin
Ural Federal University
Email: matyhin53@mail.ru
Россия, Ekaterinburg
A. Matyukhina
Ural Federal University
Email: matyhin53@mail.ru
Россия, Ekaterinburg
Дополнительные файлы