Effects of Electrolyte Composition on Heat Exchange in Anode Plasma Electrolyte Treatment of Commercial Titanium
- Autores: Zhirov A.V.1, Shadrin S.Y.1, Belkin P.N.1
-
Afiliações:
- Kostroma State University
- Edição: Volume 54, Nº 2 (2018)
- Páginas: 136-141
- Seção: Article
- URL: https://bakhtiniada.ru/1068-3755/article/view/230617
- DOI: https://doi.org/10.3103/S1068375518020151
- ID: 230617
Citar
Resumo
The study considers heat exchange in a three-phase system: electrolyte solution—vapour-gas envelope (VGE)—a titanium workpiece. The temperature of a workpiece, current intensity, heat fluxes from the envelope to the electrolyte and the workpiece were measured in an aqueous solution of ammonium chloride with addition of ammonia and glycerol. Addition of ammonia and glycerol proved to decrease current intensity, heating temperature, total energy liberation and heat fluxes to the solution and the sample. Furthermore, it was found that heat shares passing to the electrolyte and the workpiece are not affected by ammonia and glycerol concentrations. The addition of ammonia and glycerol affect heat exchange, increasing the VGE thickness due to intense evaporation of these elements.