Role of Prebreakdown Currents in a Static Breakdown of a Two-Sectioned Cold-Cathode Thyratron


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The data on prebreakdown currents and static breakdown voltages measured in two-sectioned sealed-off thyratron with a cold cathode TPI1-10k/50 are presented. The temporal behavior of the anode voltage and of the voltage at the separate sections has been investigated at the prebreakdown and breakdown stages. It is demonstrated that the prebreakdown current presented in the separate sections causes redistribution of the anode voltage between the sections. Due to this effect, a maximum thyratron breakdown voltage can be obtained. The other method to increase the breakdown voltage is based on the forced distribution of the anode voltage between the sections using a capacitive divider. Special features of transition from the prebreakdown to breakdown current are discussed for different thyratron-switching circuits.

作者简介

Yu. Korolev

Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences

编辑信件的主要联系方式.
Email: korolev@lnp.hcei.tsc.ru
俄罗斯联邦, Tomsk

N. Landl

Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences

Email: korolev@lnp.hcei.tsc.ru
俄罗斯联邦, Tomsk

V. Geyman

Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences

Email: korolev@lnp.hcei.tsc.ru
俄罗斯联邦, Tomsk

O. Frants

Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences

Email: korolev@lnp.hcei.tsc.ru
俄罗斯联邦, Tomsk

G. Argunov

Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences

Email: korolev@lnp.hcei.tsc.ru
俄罗斯联邦, Tomsk

A. Bolotov

Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences

Email: korolev@lnp.hcei.tsc.ru
俄罗斯联邦, Tomsk

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, part of Springer Nature, 2019