Controlling the peripheral temperature of the blast furnace


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Increase in FeO content lowers the initial melting temperature of primary slags in the blast furnace and prevents the formation of stable surface coatings. That increases the thermal loads on the coolers in the bosh and bosh extension and correspondingly increases the heat losses. The FeO content in the primary slags is determined by the indirect reduction. In the present work, means of reducing the thermal loads on the coolers in the bosh and bosh extension are assessed. Decrease in the gas temperature at the furnace periphery is accompanied by change in the degree of indirect reduction. Hence, the peripheral temperature may be regarded as an indicator of the degree of indirect reduction. A model of the gas temperature and the reducing effect of the gas at the furnace periphery is developed and may be used to optimize the thermal state of the furnace shaft in the peripheral zone.

作者简介

S. Zagainov

Ural Federal University

编辑信件的主要联系方式.
Email: zagainovsky@mail.ru
俄罗斯联邦, Yekaterinburg

S. Filatov

OAO Novolipetskii Metallurgicheskii Kombinat (NLMK)

Email: zagainovsky@mail.ru
俄罗斯联邦, Lipetsk

L. Gileva

Ural Federal University

Email: zagainovsky@mail.ru
俄罗斯联邦, Yekaterinburg

A. Lozovich

Ural Federal University

Email: zagainovsky@mail.ru
俄罗斯联邦, Yekaterinburg

S. Jimoh

Ural Federal University

Email: zagainovsky@mail.ru
俄罗斯联邦, Yekaterinburg

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2016