HPLC-MS/MS Method for Determining Dabigatran in Human Blood Serum


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

An HPLC-MS/MS method for determining dabigatran in human blood serum was developed. Samples were prepared by precipitation of proteins using MeOH followed by centrifugation and dilution with deionized H2O. The developed method had a simple sample-preparation procedure, short analysis time, and wide analytical range (from 1 to 1,000 ng/mL). This method was suitable for routine bioanalytical studies, in particular, therapeutic drug monitoring.

Sobre autores

T. Rodina

Scientific Center for Expert Evaluation of Medical Products, Ministry of Health of the Russian Federation; I. V. Davydovsky Municipal Clinical Hospital, Moscow City Department of Health

Email: chem@folium.ru
Rússia, 8/2 Petrovskii Blvd., Moscow, 127051; 11 Yauzskaya St., Moscow, 109240

E. Mel’nikov

I. V. Davydovsky Municipal Clinical Hospital, Moscow City Department of Health; I. M. Sechenov First Moscow State Medical University, Ministry of Health of the Russian Federation (Sechenov University)

Email: chem@folium.ru
Rússia, 11 Yauzskaya St., Moscow, 109240; 8/2 Trubetskaya St., Moscow, 119991

A. Aksenov

Scientific Center for Expert Evaluation of Medical Products, Ministry of Health of the Russian Federation; I. M. Sechenov First Moscow State Medical University, Ministry of Health of the Russian Federation (Sechenov University)

Email: chem@folium.ru
Rússia, 8/2 Petrovskii Blvd., Moscow, 127051; 8/2 Trubetskaya St., Moscow, 119991

S. Belkov

Scientific Center for Expert Evaluation of Medical Products, Ministry of Health of the Russian Federation; I. V. Davydovsky Municipal Clinical Hospital, Moscow City Department of Health; I. M. Sechenov First Moscow State Medical University, Ministry of Health of the Russian Federation (Sechenov University)

Email: chem@folium.ru
Rússia, 8/2 Petrovskii Blvd., Moscow, 127051; 11 Yauzskaya St., Moscow, 109240; 8/2 Trubetskaya St., Moscow, 119991

A. Sokolov

Scientific Center for Expert Evaluation of Medical Products, Ministry of Health of the Russian Federation; I. M. Sechenov First Moscow State Medical University, Ministry of Health of the Russian Federation (Sechenov University)

Email: chem@folium.ru
Rússia, 8/2 Petrovskii Blvd., Moscow, 127051; 8/2 Trubetskaya St., Moscow, 119991

A. Prokof’ev

Scientific Center for Expert Evaluation of Medical Products, Ministry of Health of the Russian Federation; I. V. Davydovsky Municipal Clinical Hospital, Moscow City Department of Health; I. M. Sechenov First Moscow State Medical University, Ministry of Health of the Russian Federation (Sechenov University)

Email: chem@folium.ru
Rússia, 8/2 Petrovskii Blvd., Moscow, 127051; 11 Yauzskaya St., Moscow, 109240; 8/2 Trubetskaya St., Moscow, 119991

G. Ramenskaya

Scientific Center for Expert Evaluation of Medical Products, Ministry of Health of the Russian Federation; I. M. Sechenov First Moscow State Medical University, Ministry of Health of the Russian Federation (Sechenov University)

Email: chem@folium.ru
Rússia, 8/2 Petrovskii Blvd., Moscow, 127051; 8/2 Trubetskaya St., Moscow, 119991

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Springer Science+Business Media, LLC, part of Springer Nature, 2018