Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

A technique for calibrating cathode strip gains in multiwire drift chambers of the GlueX experiment is described. The accuracy of the technique is estimated based on Monte Carlo generated data with known gain coefficients in the strip signal channels. One of the four detector sections has been calibrated using cosmic rays. Results of drift chamber calibration on the accelerator beam upon inclusion in the GlueX experimental setup are presented.

Sobre autores

V. Berdnikov

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Autor responsável pela correspondência
Email: vvberdnikov@gmail.com
Rússia, Kashirskoe sh. 31, Moscow, 115409

S. Somov

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Email: vvberdnikov@gmail.com
Rússia, Kashirskoe sh. 31, Moscow, 115409

L. Pentchev

Thomas Jefferson National Accelerator Facility

Email: vvberdnikov@gmail.com
Estados Unidos da América, 12000 Jefferson Avenue, Newport News, Virginia, 23606

A. Somov

Thomas Jefferson National Accelerator Facility

Email: vvberdnikov@gmail.com
Estados Unidos da América, 12000 Jefferson Avenue, Newport News, Virginia, 23606

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Pleiades Publishing, Inc., 2016